T11 · OPENRGD RESEARCH · PHYSICAL EVIDENCE

A robot can have a valid calibration file and still be physically uncalibrated.

Offline model inspection, calibration records, physical measurements and runtime actuation permission are distinct boundaries. OpenRGD’s Rust calibration module was designed to keep missing evidence visible rather than quietly infer current joint truth.

MATURITYRESEARCH THESIS · Read-only Rust module tested; physical acceptance pending.
LAST VERIFIED18 Nov 2026
SOURCE VERSIONOpenRGD Research Thesis Register v1.0 · pinned project sources
EVIDENCE BOUNDARYNo active calibration, authenticated measurement chain, stereo metrology acceptance or motor-control permission is established.

RESEARCH POSITION

Our hypothesis and its strongest alternative.

HYPOTHESIS

Claim under test

Nominal description, saved calibration claims, measured values and motor readiness should be distinct states; passive validation must not authorize homing or motion.

COUNTER-HYPOTHESIS

Alternative explanation

Schema-valid calibration files and matching hashes are sufficient to certify current physical calibration and control readiness.

Distinctive contribution: The original engineering contribution is a passive, deterministic, source-pinned calibration-consistency report with explicit non-actuation semantics; it is not a replacement for traceable metrology or physical commissioning.

THE FOUR DIFFERENT CLAIMS

Nominal, declared, measured and authorized must not collapse.

A robot model can specify a nominal joint zero and mechanically allowable range. A saved calibration profile can declare a correction. A measured observation can estimate an actual state under time, uncertainty and instrument constraints. A physical runtime must independently decide whether commanding that joint is permitted.

Those four claims are easy to blur in software. A parser may return an offset value, but the file does not prove which physical robot produced it, whether the measurement was valid, whether the sensor changed afterward or whether movement is safe right now.

SOFTWARE EVIDENCE

CAL-0.2 already demonstrates a conservative offline approach.

The merged CAL-0.2 Rust module inspects a local canonical profile without opening a bus or moving a motor. The module performs bounded JSON/JSONC parsing, raw-source SHA-256 recording, candidate field inventory, orphan/unresolved reference diagnostics and optional unapplied correction previews. Its acceptance record reports 31 passing tests plus CLI smoke runs.

A pinned canonical-reference smoke identified candidate/declared fields, but zero independently observed physical measurements. The report deliberately states current_robot_position_observed: false and claims_physical_calibration_certified: false. This is a successful trust-boundary test, not evidence that Paky-01 is physically calibrated.

PHYSICAL MEASUREMENT GATE

Hashing a claimed correction does not establish metrological traceability.

The international metrology vocabulary defines traceability in relation to a documented calibration chain and uncertainty. In practical robot terms, we need to identify the physical instrument, reference, procedure, time, environmental conditions and uncertainty, not simply a file digest.

CAL-0.3 proposes an offline stereo OCCHI capture/calibration workflow and has passed synthetic tests; real capture and physical/metrological acceptance remain pending. Synthetic corner detections cannot establish that a real stereo baseline produces accurate metric depth.

HOW TO FALSIFY IT

Deliberately give the inspector a plausible but wrong robot.

The proposed adversarial corpus should use valid JSON with a mismatched physical-instance claim, orphan actuator IDs, stale sensor calibration, a contradictory model digest and missing observations. The passive report should refuse to upgrade any of these into present physical truth.

A separately supervised hardware calibration test would then compare measured outcomes with declared values and uncertainty. If software automatically grants motion or asserts observed position before independent measurement, the system violates the thesis.

POTENTIAL FALSIFIER

What finding would count against the thesis?

If the passive module reports actual position, verified physical correction or motion permission without trusted measurements, its boundary fails.

Alternative: Schema-valid calibration files and matching hashes are sufficient to certify current physical calibration and control readiness.

NEXT PROTOCOL

Design a test that could fail.

01Nominal model→
02Declared calibration→
03Offline consistency checks→
04External measured evidence→
05Uncertainty / provenance review→
06Unapplied candidate correction→
07Independent hardware authorization

Adversarially change instance/model hashes, orphan actuator IDs and calibration references; then perform separately supervised real measurement with uncertainty if permitted.

01

Correct hash with wrong physical instance

An explicit negative case to report as accepted, rejected or unresolved—not omit from the denominator.

02

Stale calibration document

An explicit negative case to report as accepted, rejected or unresolved—not omit from the denominator.

03

Missing joint sensor evidence

An explicit negative case to report as accepted, rejected or unresolved—not omit from the denominator.

04

Orphan actuator mapping

An explicit negative case to report as accepted, rejected or unresolved—not omit from the denominator.

05

Forged validation state

An explicit negative case to report as accepted, rejected or unresolved—not omit from the denominator.

06

Synthetic stereo data labeled physical

An explicit negative case to report as accepted, rejected or unresolved—not omit from the denominator.

METRICS AND EVIDENCE GATE

What must be recorded before a stronger claim is justified?

MEASURE 01

Input file hashes and canonical model pin

Required evidence field for this planned protocol.

MEASURE 02

Declared vs observed coverage counts

Required evidence field for this planned protocol.

MEASURE 03

Unresolved/orphan reference count

Required evidence field for this planned protocol.

MEASURE 04

Measurement uncertainty and traceability

Required evidence field for this planned protocol.

MEASURE 05

False certified or applied report fields

Required evidence field for this planned protocol.

MEASURE 06

Observed physical error under supervised acceptance

Required evidence field for this planned protocol.

Publication gate: Require calibration-report digest, traceable measurements with uncertainty, hardware binding and independent acceptance; keep preview unapplied.

CURRENT EVIDENCE & LIMITS

Evidence is useful only when its boundary stays visible.

What exists: CAL-0.2 is merged on main with 31 Rust tests and offline reference inspection; CAL-0.3 optical workflow has synthetic tests only.

What remains unknown: No active calibration, authenticated measurement chain, stereo metrology acceptance or motor-control permission is established.

Current maturity: Read-only Rust module tested; physical acceptance pending.. This page is a research dossier, not an accepted OpenRGD normative contract.